Top

2026-35-A1LF Datasheet

2026-35-A1LF Cover
Datasheet2026-35-A1LF
File Size734.67 KB
Total Pages5
ManufacturerBourns
Websitehttp://www.bourns.com/
Total PartsThis datasheet covers 202 part numbers
Associated Parts 2026-35-A1LF, 2026-42-ALF, 2026-25-ALF, 2026-35-A1FLF, 2026-40-CF, 2026-09-A1FLF, 2026-60-C3FLF, 2026-47-C4FLF, 2026-47-C3FLF, 2026-42-C3FLF, 2026-40-C3FLF, 2026-35-C3FLF, 2026-30-C3FLF, 2026-26-C3FLF, 2026-25-C3FLF, 2026-25-A1FLF, 2026-20-C3FLF, 2026-15-C3FLF, 2026-09-C3FLF, 2026-07-C3FLF, 2026-09-C2FLF, 2026-07-C2FLF, 2026-60-C2FLF, 2026-47-C2FLF, 2026-47-C2F, 2026-42-C4FLF, 2026-42-C2FLF, 2026-40-C2FLF, 2026-40-C13F, 2026-35-C4FLF, 2026-35-C4F, 2026-30-C2FLF, 2026-26-C2FLF, 2026-25-C2FLF, 2026-23-CF, 2026-23-C4F, 2026-23-C3FLF, 2026-23-C2FLF, 2026-23-A1FLF, 2026-20-C2FLF , etc.
Description GDT 350V 20% 20KA 3POLE, GDT ARRESTOR 420V TH, GDT ARRESTOR 250V TH, GAS DISCHARGE TUBE, GDT 400V 20KA 3 POLE

2026-35-A1LF - Bourns

2026-35-A1LF Datasheet Page 1
2026-35-A1LF Datasheet Page 2
2026-35-A1LF Datasheet Page 3
2026-35-A1LF Datasheet Page 4
2026-35-A1LF Datasheet Page 5

The Products You May Be Interested In

2026-35-A1LF 2026-35-A1LF Bourns GDT 350V 20% 20KA 3POLE 602

More on Order

2026-42-ALF 2026-42-ALF Bourns GDT ARRESTOR 420V TH 565

More on Order

2026-25-ALF 2026-25-ALF Bourns GDT ARRESTOR 250V TH 573

More on Order

2026-35-A1FLF 2026-35-A1FLF Bourns GAS DISCHARGE TUBE 295

More on Order

2026-40-CF 2026-40-CF Bourns GDT 400V 20KA 3 POLE 482

More on Order

2026-09-A1FLF 2026-09-A1FLF Bourns GDT 90V 20KA 3 POLE 331

More on Order

2026-60-C3FLF 2026-60-C3FLF Bourns GDT 600V 20% 20KA T/H FAIL SHORT 492

More on Order

2026-47-C4FLF 2026-47-C4FLF Bourns GDT 470V 20% 20KA T/H FAIL SHORT 448

More on Order

2026-47-C3FLF 2026-47-C3FLF Bourns GDT 470V 20% 20KA T/H FAIL SHORT 341

More on Order

2026-42-C3FLF 2026-42-C3FLF Bourns GDT 420V 20% 20KA T/H FAIL SHORT 509

More on Order

2026-40-C3FLF 2026-40-C3FLF Bourns GDT 400V 20% 20KA T/H FAIL SHORT 420

More on Order

2026-35-C3FLF 2026-35-C3FLF Bourns GDT 350V 20% 20KA T/H FAIL SHORT 356

More on Order

URL Link

2026-35-A1LF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

350V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

No

Mounting Type

User Defined

Package / Case

Cylinder No Lead, 3 Terminal

2026-42-ALF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

420V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

No

Mounting Type

User Defined

Package / Case

Cylinder No Lead, 3 Terminal

2026-25-ALF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

250V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

No

Mounting Type

User Defined

Package / Case

Cylinder No Lead, 3 Terminal

2026-35-A1FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

350V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

User Defined

Package / Case

Cylinder No Lead, 3 Terminal

2026-40-CF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

400V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (T-Shape)

2026-09-A1FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

90V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

User Defined

Package / Case

Cylinder 1 Lead, 3 Terminal

2026-60-C3FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

600V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (Radial Bend)

2026-47-C4FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

470V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (Radial Bend)

2026-47-C3FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

470V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (Radial Bend)

2026-42-C3FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

420V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (Radial Bend)

2026-40-C3FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

400V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (Radial Bend)

2026-35-C3FLF

Bourns

Manufacturer

Bourns Inc.

Series

TRIGARD® 2026

Voltage - DC Spark Over (Nom)

350V

Impulse Discharge Current (8/20µs)

20000A (20kA)

Tolerance

±20%

Number of Poles

3

Fail Short

Yes

Mounting Type

Through Hole

Package / Case

Axial Cylinder, 3 Lead (Radial Bend)