Top

2037-60-CLF Datasheet

2037-60-CLF Cover
Datasheet2037-60-CLF
File Size181.22 KB
Total Pages3
ManufacturerBourns
Websitehttp://www.bourns.com/
Total PartsThis datasheet covers 112 part numbers
Associated Parts 2037-60-CLF, 2037-40-CLF, 2037-35-CLF, 2037-60-C, 2037-40-C, 2037-35-C, 2037-30-C5, 2037-30-C, 2037-25-C5, 2037-09-C5, 2037-09-C, 2037-09-B5LF, 2037-25-B5LF, 2037-60-B5LF, 2037-60-B5, 2037-42-B5LF, 2037-35-B5LF, 2037-35-B5, 2037-30-B5, 2037-25-B5, 2037-23-B5, 2037-20-B5, 2035-60-BT1LF, 2035-25-B5LF, 2035-47-BT1LF, 2035-47-B5LF, 2035-35-B5LF, 2035-30-B5LF, 2035-23-B5LF, 2035-20-BT1LF, 2035-15-BT1LF, 2035-15-B5LF, 2035-60-B5, 2035-40-B5, 2035-35-BT1LF, 2035-35-BT1, 2035-35-B5, 2035-30-B5, 2035-25-B5, 2035-23-BT1 , etc.
Description GDT 600V 15% 5KA THROUGH HOLE, GDT 400V 15% 5KA THROUGH HOLE, GDT 350V 15% 5KA THROUGH HOLE, GDT 600V 15% 5KA THROUGH HOLE, GDT 400V 15% 5KA THROUGH HOLE

2037-60-CLF - Bourns

2037-60-CLF Datasheet Page 1
2037-60-CLF Datasheet Page 2
2037-60-CLF Datasheet Page 3

The Products You May Be Interested In

2037-60-CLF 2037-60-CLF Bourns GDT 600V 15% 5KA THROUGH HOLE 533

More on Order

2037-40-CLF 2037-40-CLF Bourns GDT 400V 15% 5KA THROUGH HOLE 269

More on Order

2037-35-CLF 2037-35-CLF Bourns GDT 350V 15% 5KA THROUGH HOLE 444

More on Order

2037-60-C 2037-60-C Bourns GDT 600V 15% 5KA THROUGH HOLE 663

More on Order

2037-40-C 2037-40-C Bourns GDT 400V 15% 5KA THROUGH HOLE 269

More on Order

2037-35-C 2037-35-C Bourns GDT 350V 15% 5KA THROUGH HOLE 635

More on Order

2037-30-C5 2037-30-C5 Bourns GDT 300V 15% 5KA THROUGH HOLE 233

More on Order

2037-30-C 2037-30-C Bourns GDT 300V 15% 5KA THROUGH HOLE 350

More on Order

2037-25-C5 2037-25-C5 Bourns GDT 250V 15% 5KA THROUGH HOLE 606

More on Order

2037-09-C5 2037-09-C5 Bourns GDT 90V 20% 5KA THROUGH HOLE 480

More on Order

2037-09-C 2037-09-C Bourns GDT 90V 20% 5KA THROUGH HOLE 591

More on Order

2037-09-B5LF 2037-09-B5LF Bourns GDT 90V 5KA 2 POLE 471

More on Order

URL Link

2037-60-CLF

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

600V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-40-CLF

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

400V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-35-CLF

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

350V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-60-C

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

600V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-40-C

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

400V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-35-C

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

350V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-30-C5

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

300V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder, Radial Bend

2037-30-C

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

300V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-25-C5

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

250V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder, Radial Bend

2037-09-C5

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

90V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±20%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder, Radial Bend

2037-09-C

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

90V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±20%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder

2037-09-B5LF

Bourns

Manufacturer

Bourns Inc.

Series

2037

Voltage - DC Spark Over (Nom)

90V

Impulse Discharge Current (8/20µs)

5000A (5kA)

Tolerance

±15%

Number of Poles

2

Fail Short

No

Mounting Type

Through Hole

Package / Case

Axial Cylinder, Radial Bend