Datasheet | AMI-M11P-6-30-B |
File Size | 4,967.98 KB |
Total Pages | 12 |
Manufacturer | Altran Magnetics |
Website | |
Total Parts | This datasheet covers 14 part numbers |
Associated Parts | AMI-M11P-6-30-B, AMI-M11P-6-20-C, AMI-M11R-7-10-B-2, AMI-M11R-7-10-B-1, AMI-M11R-7M-10-B-1, AMI-M11R-7M-6-B-1, AMI-M11R-7M-6-B-2, AMI-M11R-7-6-B-2, AMI-M11P-3-6-B-1, AMI-M11P-1-6-B-1, AMI-M11P-1-6-B-2, AMI-M11R-7-3-B-2, AMI-M11P-1-3-B-2, AMI-M11P-3-3-B-1 |
Description | LINE FILTER 250VAC 30A CHASS MNT, LINE FILTER 250VAC 20A CHASS MNT, LINE FILTER 250VAC 10A CHASS MNT, LINE FILTER 250VAC 10A CHASS MNT, LINE FILTER 250VAC 10A CHASS MNT |
AMI-M11P-6-30-B - Altran Magnetics
The Products You May Be Interested In
AMI-M11P-6-30-B | Altran Magnetics | LINE FILTER 250VAC 30A CHASS MNT | 549 More on Order |
|
AMI-M11P-6-20-C | Altran Magnetics | LINE FILTER 250VAC 20A CHASS MNT | 563 More on Order |
|
AMI-M11R-7-10-B-2 | Altran Magnetics | LINE FILTER 250VAC 10A CHASS MNT | 386 More on Order |
|
AMI-M11R-7-10-B-1 | Altran Magnetics | LINE FILTER 250VAC 10A CHASS MNT | 375 More on Order |
|
AMI-M11R-7M-10-B-1 | Altran Magnetics | LINE FILTER 250VAC 10A CHASS MNT | 407 More on Order |
|
AMI-M11R-7M-6-B-1 | Altran Magnetics | LINE FILTER 250VAC 6A CHASS MNT | 414 More on Order |
|
AMI-M11R-7M-6-B-2 | Altran Magnetics | LINE FILTER 250VAC 6A CHASS MNT | 426 More on Order |
|
AMI-M11R-7-6-B-2 | Altran Magnetics | LINE FILTER 250VAC 6A CHASS MNT | 512 More on Order |
|
AMI-M11P-3-6-B-1 | Altran Magnetics | LINE FILTER 250VAC 6A CHASS MNT | 249 More on Order |
|
AMI-M11P-1-6-B-1 | Altran Magnetics | LINE FILTER 250VAC 6A CHASS MNT | 558 More on Order |
|
AMI-M11P-1-6-B-2 | Altran Magnetics | LINE FILTER 250VAC 6A CHASS MNT | 465 More on Order |
|
AMI-M11R-7-3-B-2 | Altran Magnetics | LINE FILTER 250VAC 3A CHASS MNT | 434 More on Order |
URL Link
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 30A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style Threaded Post (10-32) Inductance 1.73mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 20A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style Threaded Post (10-32) Inductance 6.06mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 10A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.13mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 10A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.13mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 10A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.13mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 6A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.8mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 6A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.8mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 6A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.8mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 6A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style Wire Leads Inductance 8.73mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 6A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style Quick Connect Inductance 8.73mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 6A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style Wire Leads Inductance 8.73mH |
Altran Magnetics Manufacturer Altran Magnetics Series * Filter Type Single Phase Configuration Single Stage Voltage - Rated DC - Voltage - Rated AC 250V Voltage - Rated AC (Phase to Ground/Neutral) - Voltage - Rated AC (Phase to Phase) - Current 3A Frequency - Operating 50/60Hz Applications General Purpose Approvals - Operating Temperature -10°C ~ 40°C Mounting Type Chassis Mount Termination Style IEC 320-C14, Quick Connect Inductance 7.06mH |