Datasheet | E3JM-10M4-US |
File Size | 1,044.54 KB |
Total Pages | 9 |
Manufacturer | Omron Automation and Safety |
Website | |
Total Parts | This datasheet covers 17 part numbers |
Associated Parts | E3JM-10M4-US, E3JM-10S4T-US, E3JM-10R4T-US, E3JM-10R4-US, E3JM-10M4T-US, E3JM-R4S4T-US, E3JM-DS70S4T-US, E3JM-DS70R4T-US, E3JM-R4R4T-US, E3JM-R4S4-US, E3JM-R4R4-US, E3JM-DS70S4-US, E3JM-DS70R4-US, E3JM-DS70M4T-US, E3JM-DS70M4-US, E3JM-R4M4-US, E3JM-R4M4TUS |
Description | SENSOR THROUGH-BEAM 10M RELAY, SENSOR RETROREFLECTIVE 1MM LO/DO, SENSOR THROUGH-BEAM 10M LO/DO, SENSOR THROUGH-BEAM 10M LO/DO, SENSOR THROUGH-BEAM 10M RELAY |
E3JM-10M4-US - Omron Automation and Safety
The Products You May Be Interested In
E3JM-10M4-US | Omron Automation and Safety | SENSOR THROUGH-BEAM 10M RELAY | 259 More on Order |
|
E3JM-10S4T-US | Omron Automation and Safety | SENSOR RETROREFLECTIVE 1MM LO/DO | 270 More on Order |
|
E3JM-10R4T-US | Omron Automation and Safety | SENSOR THROUGH-BEAM 10M LO/DO | 319 More on Order |
|
E3JM-10R4-US | Omron Automation and Safety | SENSOR THROUGH-BEAM 10M LO/DO | 203 More on Order |
|
E3JM-10M4T-US | Omron Automation and Safety | SENSOR THROUGH-BEAM 10M RELAY | 641 More on Order |
|
E3JM-R4S4T-US | Omron Automation and Safety | SENSOR RETROREFLECTIVE 4M LO/DO | 287 More on Order |
|
E3JM-DS70S4T-US | Omron Automation and Safety | SENSOR REFLECTIVE 700MM LO/DO | 237 More on Order |
|
E3JM-DS70R4T-US | Omron Automation and Safety | SENSOR REFLECTIVE 700MM LO/DO | 184 More on Order |
|
E3JM-R4R4T-US | Omron Automation and Safety | SENSOR RETROREFLECTIVE 4M LO/DO | 308 More on Order |
|
E3JM-R4S4-US | Omron Automation and Safety | SENSOR RETROREFLECTIVE 4M LO/DO | 314 More on Order |
|
E3JM-R4R4-US | Omron Automation and Safety | SENSOR RETROREFLECTIVE 4M LO/DO | 314 More on Order |
|
E3JM-DS70S4-US | Omron Automation and Safety | SENSOR REFLECTIVE 700MM LO/DO | 202 More on Order |
URL Link
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Through-Beam Sensing Distance 393.7" (10m) 32.8' Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 30ms Output Configuration Relay - Dark-ON/Light-ON - Selectable Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Retroreflective Sensing Distance 0.039" (1mm) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 30ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Through-Beam Sensing Distance 393.7" (10m) 32.8' Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 30ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Through-Beam Sensing Distance 393.7" (10m) 32.8' Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 30ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Through-Beam Sensing Distance 393.7" (10m) 32.8' Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 30ms Output Configuration Relay - Dark-ON/Light-ON - Selectable Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Retroreflective Sensing Distance 157.480" (4m) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Red (660nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Reflective, Diffuse Sensing Distance 27.559" (700mm) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type Single-Turn Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Reflective, Diffuse Sensing Distance 27.559" (700mm) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type Single-Turn Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Retroreflective Sensing Distance 157.480" (4m) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Red (660nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Retroreflective Sensing Distance 157.480" (4m) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Red (660nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Retroreflective Sensing Distance 157.480" (4m) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Red (660nm) Adjustment Type - Operating Temperature -25°C ~ 55°C |
Omron Automation and Safety Manufacturer Omron Automation and Safety Series E3JM Sensing Method Reflective, Diffuse Sensing Distance 27.559" (700mm) Voltage - Supply 12V ~ 240V, 24V ~ 240V Response Time 5ms Output Configuration Light-On/Dark-On Connection Method Terminal Block Ingress Protection IEC IP66 Cable Length - Light Source Infrared (950nm) Adjustment Type Single-Turn Operating Temperature -25°C ~ 55°C |