Datasheet | ER11/2.5/6-3C97-A100-S |
File Size | 73.83 KB |
Total Pages | 2 |
Manufacturer | Ferroxcube |
Website | |
Total Parts | This datasheet covers 12 part numbers |
Associated Parts | ER11/2.5/6-3C97-A100-S, ER11/2.5/6-3C95-A100-S, ER11/2.5/6-3F46-A100-S, ER11/2.5/6-3C97-S, ER11/2.5/6-3C95-S, ER11/2.5/6-3F46-S, ER11/2.5/6-3F36-A100-S, ER11/2.5/6-3C92-A100-S, ER11/2.5/6-3C96-A100-S, ER11/2.5/6-3F36-S, ER11/2.5/6-3C96-S, ER11/2.5/6-3C92-S |
Description | PLANAR ER CORES 2PC SET, PLANAR ER CORES 2PC SET, PLANAR ER CORES 2PC SET, PLANAR ER CORES 2PC SET, PLANAR ER CORES 2PC SET |
ER11/2.5/6-3C97-A100-S - Ferroxcube
The Products You May Be Interested In
ER11/2.5/6-3C97-A100-S | Ferroxcube | PLANAR ER CORES 2PC SET | 503 More on Order |
|
ER11/2.5/6-3C95-A100-S | Ferroxcube | PLANAR ER CORES 2PC SET | 280 More on Order |
|
ER11/2.5/6-3F46-A100-S | Ferroxcube | PLANAR ER CORES 2PC SET | 290 More on Order |
|
ER11/2.5/6-3C97-S | Ferroxcube | PLANAR ER CORES 2PC SET | 357 More on Order |
|
ER11/2.5/6-3C95-S | Ferroxcube | PLANAR ER CORES 2PC SET | 186 More on Order |
|
ER11/2.5/6-3F46-S | Ferroxcube | PLANAR ER CORES 2PC SET | 279 More on Order |
|
ER11/2.5/6-3F36-A100-S | Ferroxcube | PLANAR ER CORES 2PC SET | 410 More on Order |
|
ER11/2.5/6-3C92-A100-S | Ferroxcube | PLANAR ER CORES 2PC SET | 458 More on Order |
|
ER11/2.5/6-3C96-A100-S | Ferroxcube | PLANAR ER CORES 2PC SET | 510 More on Order |
|
ER11/2.5/6-3F36-S | Ferroxcube | PLANAR ER CORES 2PC SET | 491 More on Order |
|
ER11/2.5/6-3C96-S | Ferroxcube | PLANAR ER CORES 2PC SET | 433 More on Order |
|
ER11/2.5/6-3C92-S | Ferroxcube | PLANAR ER CORES 2PC SET | 302 More on Order |
URL Link
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C97 Diameter - Inductance Factor (Al) 100nH Tolerance ±4% Gap Gapped Effective Permeability (µe) 98 Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C95 Diameter - Inductance Factor (Al) 100nH Tolerance ±4% Gap Gapped Effective Permeability (µe) 98 Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3F46 Diameter - Inductance Factor (Al) 100nH Tolerance ±4% Gap Gapped Effective Permeability (µe) 98 Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C97 Diameter - Inductance Factor (Al) - Tolerance ±25% Gap Ungapped Effective Permeability (µe) - Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C95 Diameter - Inductance Factor (Al) - Tolerance ±25% Gap Ungapped Effective Permeability (µe) - Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3F46 Diameter - Inductance Factor (Al) - Tolerance ±25% Gap Ungapped Effective Permeability (µe) - Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3F36 Diameter - Inductance Factor (Al) 100nH Tolerance ±4% Gap Gapped Effective Permeability (µe) 98 Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C92 Diameter - Inductance Factor (Al) 100nH Tolerance ±4% Gap Gapped Effective Permeability (µe) 98 Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C96 Diameter - Inductance Factor (Al) 100nH Tolerance ±4% Gap Gapped Effective Permeability (µe) 98 Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3F36 Diameter - Inductance Factor (Al) - Tolerance ±25% Gap Ungapped Effective Permeability (µe) - Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C96 Diameter - Inductance Factor (Al) - Tolerance ±25% Gap Ungapped Effective Permeability (µe) - Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |
Ferroxcube Manufacturer Ferroxcube Series * Core Type ER Supplier Device Package ER 11 x 2.5 x 6 Material 3C92 Diameter - Inductance Factor (Al) - Tolerance ±25% Gap Ungapped Effective Permeability (µe) - Initial Permeability (µi) - Core Factor (ΣI/A) mm1 1.23 Effective Length (le) mm 14.7 Effective Area (Ae) mm² 11.9 Minimum Core Cross Section (Amin) mm² 10.3 Effective Magnetic Volume (Ve) mm³ 174 Finish Uncoated Height 6.00mm Length 11.00mm Width 2.45mm |