Datasheet | THM 20-4821 |
File Size | 943.24 KB |
Total Pages | 5 |
Manufacturer | Traco Power |
Website | |
Total Parts | This datasheet covers 21 part numbers |
Associated Parts | THM 20-4821, THM 20-1221, THM 20-2421, THM 20-4823, THM 20-4822, THM 20-2423, THM 20-2422, THM 20-1223, THM 20-1222, THM 20-4811, THM 20-2411, THM 20-1211, THM 20-4813, THM 20-4815, THM 20-1215, THM 20-1213, THM 20-2415, THM 20-4812, THM 20-2413, THM 20-1212, THM 20-2412 |
Description | DC DC CONVERTER +/-5V 20W, DC DC CONVERTER +/-5V 20W, DC DC CONVERTER +/-5V 20W, DC DC CONVERTER +/-15V 20W, DC DC CONVERTER +/-12V 20W |
THM 20-4821 - Traco Power
The Products You May Be Interested In
THM 20-4821 | Traco Power | DC DC CONVERTER +/-5V 20W | 385 More on Order |
|
THM 20-1221 | Traco Power | DC DC CONVERTER +/-5V 20W | 420 More on Order |
|
THM 20-2421 | Traco Power | DC DC CONVERTER +/-5V 20W | 428 More on Order |
|
THM 20-4823 | Traco Power | DC DC CONVERTER +/-15V 20W | 641 More on Order |
|
THM 20-4822 | Traco Power | DC DC CONVERTER +/-12V 20W | 523 More on Order |
|
THM 20-2423 | Traco Power | DC DC CONVERTER +/-15V 20W | 517 More on Order |
|
THM 20-2422 | Traco Power | DC DC CONVERTER +/-12V 20W | 427 More on Order |
|
THM 20-1223 | Traco Power | DC DC CONVERTER +/-15V 20W | 468 More on Order |
|
THM 20-1222 | Traco Power | DC DC CONVERTER +/-12V 20W | 554 More on Order |
|
THM 20-4811 | Traco Power | DC DC CONVERTER 5V 20W | 664 More on Order |
|
THM 20-2411 | Traco Power | DC DC CONVERTER 5V 20W | 417 More on Order |
|
THM 20-1211 | Traco Power | DC DC CONVERTER 5V 20W | 458 More on Order |
URL Link
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 36V Voltage - Input (Max) 75V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 2A, 2A Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 86% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 18V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 2A, 2A Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 86% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 18V Voltage - Input (Max) 36V Voltage - Output 1 5V Voltage - Output 2 -5V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 2A, 2A Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 86% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 36V Voltage - Input (Max) 75V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 667mA, 667mA Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 88% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 36V Voltage - Input (Max) 75V Voltage - Output 1 12V Voltage - Output 2 -12V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 833mA, 833mA Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 88.5% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 18V Voltage - Input (Max) 36V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 667mA, 667mA Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 90% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 18V Voltage - Input (Max) 36V Voltage - Output 1 12V Voltage - Output 2 -12V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 833mA, 833mA Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 90% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 18V Voltage - Output 1 15V Voltage - Output 2 -15V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 667mA, 667mA Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 89% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 2 Voltage - Input (Min) 9V Voltage - Input (Max) 18V Voltage - Output 1 12V Voltage - Output 2 -12V Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 833mA, 833mA Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 89% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 36V Voltage - Input (Max) 75V Voltage - Output 1 5V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 4A Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 89.5% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 18V Voltage - Input (Max) 36V Voltage - Output 1 5V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 4A Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 90% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |
Traco Power Manufacturer Traco Power Series THM 20 (20W) Type Isolated Module Number of Outputs 1 Voltage - Input (Min) 9V Voltage - Input (Max) 18V Voltage - Output 1 5V Voltage - Output 2 - Voltage - Output 3 - Voltage - Output 4 - Current - Output (Max) 4A Power (Watts) 20W Voltage - Isolation 5kV Applications Medical Features OCP, OTP, OVP, SCP Operating Temperature -40°C ~ 80°C (With Derating) Efficiency 87% Mounting Type Through Hole Package / Case 5-DIP Module Size / Dimension 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Supplier Device Package - Control Features |